* Hart protocol current output pressure sensor indicator with LCD display (JC625-21)

JC625-21 Pressure Transducer Indicator with LCD Display Overview:JC625-21 pressure transducer indicator with LCD display is provided with foreign advanced sensor force-sensitive chips, supported with high-accuracy electronic elements, and assembled through strict process flow. This series of products is provided with special ter

Featured Products

* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)

JC625-21 Pressure Transducer Indicator with LCD Display Overview:

JC625-21 pressure transducer indicator with LCD display is provided with foreign advanced sensor force-sensitive chips, supported with high-accuracy electronic elements, and assembled through strict process flow. This series of products is provided with special terminals, shield cables, pointers and digital display, with easy installation, calibration and maintenance. It can be extensively used in many industrial fields such as petroleum, chemical, electric power, metallurgical, pharmaceutical and food industry fields etc.. Thus, this product is considered ideal for upgrading conventional pressure gauges and pressure transducers, and also serves as an ideal instrument for pressure measurement and  control in industrial automation field.

JC625-21 Pressure Transducer Indicator with LCD Display Features:
* Laser resistor trimming temperature compensation
* Adjustable zero position and range
* High accuracy, high reliability and high stability
* Radio frequency immunity
* Power reverse polarity and over-voltage protection
* Isolating corrosion-proof, and intrinsic safe explosion-proof
* Direct process installation, field pointer or digital display.
* Standard intelligent 4 ~ 20 mA, HART protocol (optional)
* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)

JC625-21 Pressure Transducer Indicator with LCD Display Application:
It can be extensively used in many industrial fields such as petroleum, chemical, electric power, metallurgical, pharmaceutical and food industry fields etc.. Thus, this product is considered ideal for upgrading conventional pressure gauges and pressure transducers, and also serves as an ideal instrument for pressure measurement and control in industrial automation field.

* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)

Technical Parameters:
Measuring rangeOptional within -100KPa~0~5KPa...100MPa
Overload capacity2 times of full-scale pressure(1.1 times of full-scale pressure for 100MPa)
Pressure typeGauge pressure or absolute pressure
Measuring mediaThe gas or liquid compatible with 316 stainless steel
Overall accuracy (nonlinearity + 
repeatability+ hysteresis)
±0.1%FS±0.25%FS±0.4%FS
Long-term stabilityTypical:±0.1%FSMaximum:±0.2%FS
Zero temperature driftTypical:±0.02%FS/ºCMaximum:±0.05%FS/ºC
Sensitivity temperature driftTypical:±0.02%FS/ºCMaximum:±0.05%FS/ºC
Range of operating temperature -40~ 125ºC 
Range of compensation temperature -20 ~ 80ºC  
Power supply12~36VDC(generally 24VDC)
Signal output4~20mA / 1~5VDC / 0~5VDC / 0.5~4.5VDC
Load resistance≤(U-12)/0.02  Ω
Signal wire connecting holeCable hole is φ8
WeightApprox.0.5kg
Response time≤2 ms
Thermal hysteresis±0.1%FS(typical value)
Enclosure protection classIP65
Safety and explosion protectionEx iaII CT6
Vibration error≤±0.01%FS(Axes X, Y, Z,200Hz/g)
Insulation resistance100MΩ,500V DC
ResolutionInfinitely small (theoretical),1/100000(normal)

Ordering Information:
JC625-21Pressure Transducer Indicator with LCD Display
 CodePressure type  
GGauge pressure (G may not be indicated)
AAbsolute pressure
 RangeMeasuring Range( 0~ X  KPa or MPa)
 CodeOverall accuracy (linearity + repeatability + hysteresis)
1±0.5%FS
2±0.25%FS
3±0.1%FS
 CodeSignal output
A14~20mA  
V11~5V DC  
V20~5V DC  
V30.5~4.5V DC       
S4~20mA,HART protocol (standard intelligent type)
 CodeAdditional functions
F1M20x1.5 external thread
F2G1/4 external thread
F0Special
L1Pointer gauge (0~100%) display
L2Four-LCD display
L3Four-LED display
PFlush-diaphragm type
EIntrinsically safe explosion-proof type Ex iaIICT5
JC625-21 (0~100KPa)  -1  -A1  -F1  -L2         Pressure Transducer Indicator with LCD Display

Tips for Type Selection
* The medium to be measured shall be compatible with the material contacting with the product.
* As an additional function code for type selection, the code "E" for intrinsically safe explosion-proof type Ex iaIICT5 denotes that power source must be supplied via safety barrier.
* For other special requirements, please discuss with us and clearly indicate them in the order.

* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)
* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)

About Jiucheng
* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)

Qualification and Certificate:
* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)

* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)


Product Packaging:
We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.
* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)


Product Transportation:
We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.
* Hart Protocol Current Output Pressure Transducer Indicator with LCD Display (JC625 -21)

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours