1 Phase 50A PCB Latch Relay Latch Relay

Basic DataDimension(mm)31.5×36.4×21.2Weight ( g )60Contact Arrangement1A/1BContact MaterialAgSnO2Ambient Temperature-45~+85ºCVibration10~50Hz,0.075mmShock1000m/s²,(100g)Specifications DataNominal Voltage9~36VDCPower Consumption<1.5WOperating Voltage7.2VMax. Motor Voltage36VMax. Switching Current120 

Featured Products

1 Phase 50A PCB Latching Relay Latching Relay1 Phase 50A PCB Latching Relay Latching Relay1 Phase 50A PCB Latching Relay Latching Relay
Basic DataDimension(mm)31.5×36.4×21.2
Weight ( g )60
Contact Arrangement1A/1B
Contact MaterialAgSnO2
Ambient Temperature-45~+85ºC
Vibration10~50Hz,0.075mm
Shock1000m/s²,(100g)
Specifications DataNominal Voltage9~36VDC
Power Consumption<1.5W
Operating Voltage7.2V
Max. Motor Voltage36V
Max. Switching Current120 A
Surge Current3000A/10ms
Motor Resistance(R±20%)60Ω
Contact Rating(Res)250VAC,120A
Contact Voltage<60mV
Contact Resistance<0.6mΩ
Dielectric StrengthMotor to Contact>4000VAC   1min
Across Open Contact>2000VAC   1min
Electrical Life>10000
Mechanical Life>100000
Pulse Time100ms~150ms
Picking-up Time<65ms
Release Time<65ms
Off Contact Distance≥0.8mm
Insulation Resistance>1000MΩ(500VDC)
1 Phase 50A PCB Latching Relay Latching Relay
1 Phase 50A PCB Latching Relay Latching Relay1 Phase 50A PCB Latching Relay Latching Relay1 Phase 50A PCB Latching Relay Latching Relay1 Phase 50A PCB Latching Relay Latching Relay1 Phase 50A PCB Latching Relay Latching Relay           Cautions of Latching Relay:

             1.Suggestions of relay's input
            (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
            you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
            (2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
            times or 2 times of value or lower driving condition plz confirm with our engineer.
            (3)Relays'contact status may be changed during transportation or installation due to impact of external force,
            therefore please reset to the required status.
 
            2.Suggestions of relay's output
            (1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
            the installation.
            (2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
            fastened and prevent relay from damages or other safety problems due to temp. Rise..
            (3)The sampling signal wires of products are limited, please do not pull or torque during installation.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours